Items |
Characteristics |
| 1 |
Operating temperature range |
- 55degrees C +105degrees C |
| 2 |
Capacitance tolerance(120Hz) |
M( 20%) |
| 3 |
Tangent of loss angle(120Hz) |
Value in Table 3 or less |
| 4 |
Leakage current(uA/after 2min.)
(or less) 2 |
0.02CV or 0.5 (whichever is the greater) |
| 5 |
ESR(100k 300kHz) |
Value in Table 3 or less |
| 6 |
Temperature characteristics
Impedance ratio at 100kHz |
-55degrees C |
Z/Z 20degrees C |
1.0 1.25 |
| +105degrees C |
Z/Z 20degrees C |
0.75 1.0 |
| 7 |
High-temperature load
105degrees C,2000Hrs.
Rated voltage applied( D 8;1000Hrs.)
(25WV->20V applied) 1 |
C/C |
Within 20% |
| Tangent of loss angle |
1.5 times of Item 3 or less |
| Leakage current |
Item 4 or less |
| 8 |
Moisture resistance
(60degrees C,90 95%RH,1000Hrs. no voltage) |
C/C |
Within 20% |
| Tangent of loss angle |
2 times of Item 3 or less |
| Leakage current |
Item 4 or less |
| 9 |
Reverse voltage guarantee |
Temporary:less than 20% of the rated voltage,
continuous:less than 10% of the rated voltage |