Items |
Characteristics |
| 1 |
Operating
temperature |
- 55degrees C +105degrees C |
| 2 |
Capacitance
tolerance(120Hz) |
M( 20%) |
| 3 |
Tangent
of loss angle(120Hz) |
Value in Table 4 or less |
| 4 |
Leakage
current(uA/2min.)(or less) 2 |
0.02CV or 0.5 (Whichever is the greater) |
| 5 |
ESR(100k 300kHz) |
Value in Table 4 or less |
| 6 |
Temperature
characteristics
Impedance ratio at 100kHz |
-55degrees C |
Z/Z 20degrees C |
1.0 1.25 |
|
+105degrees C |
Z/Z 20degrees C |
0.75 1.0 |
| 7 |
High-temperature
load 105degrees C,
5000Hrs. Rated voltage applied
(25WV->20V applied) 1 |
C/C |
Within 30% |
|
Tangent of loss angle |
1.5 times of Item 3 or less |
|
Leakage current |
5 times of Item 4 or less |
| 8 |
Moisture
resistance
(60degrees C,90 95%CRH,1000Hrs. no voltage) |
C/C |
Within 10% |
|
Tangent of loss angle |
1.5 times of Item 3 or less |
|
Leakage current |
Item 4 or less |
| 9 |
Reverse
voltage guarantee |
Temporary:less
than 20% of the rated voltage,
Continuous;less than 10% of the rated voltage |